VX CAD-CAM Logo
Any: Find articles with any keyword.
All: Find articles with all keywords (in any order).
Exact: Find articles with exact keywords (complete title must match exactly).
Title: Search titles only.
Content: Search article content only.
Both: Search both Articles and Content.
  VXCAD Base                   Jump to:
 
Knowledge Base Home Home | Knowledge Base Index Index | Sign Up as Writer Sign Up | Knowledge Base Glossary Glossary | Contact Us Contact Us
Home > All Categories > 12. VX Import & Export > Importing Files > IGES Import Options
Question Title IGES Import Options

File > Import > Set IGES Options

Iges Import OptionsUse this form to perform various tasks while importing an IGES file.

  • Complete the form as desired and  pick OK to accept the current selections as the new defaults or Reset to return all selections to their previous defaults.

 

Forms and Dialogues General

  • Auto sew geometry
    Closed surface volumes will be sewed (joined) at their mating edges to form a solid once they have been imported into VX. This option requires that the imported edges fall within tolerance of each other.

    If importing directly into an existing object or one that is currently active, the default tolerance displayed in the Part Settings Form is used. If importing into a new object (created during the import), the default system tolerance (0.1mm) is used.

  • Auto activate part
    The imported file will be automatically activated for editing (i.e., it will become the active part).

  • Rename layer collisions
    If the IGES file is being merged into the active part or drawing sheet and it contains references to layer names that already exist, the IGES file layer name references are renamed. If this option is not checked, then the contents of the layers are merged with the existing layers.

  • Remove duplicate surfaces
    If there are duplicate trimmed surfaces, the duplicate is thrown away if this option is selected; otherwise, the duplicates goes to a layer named ’DUPLICAT’.

  • Break trim edges
    Trim loops will be evaluated for tangent discontinuities and broken if required.

  • Reset Dependencies
    It is not uncommon for third party IGES files to contain incorrect dependency flags causing entities to not import, or to import more than once. Use this option to flushes the dependencies reported in the file, and recreate them based on the entity references from the parameter section of the IGES file.

  • Force close
    Use this option to force the closure of the imported part if possible.  Some healing techniques may be used, such as trimming dangling edges or spanning missing surfaces.  This option is not recommended unless you are sure the geometry should be a closed solid.

 

Forms and Dialogues Specific

  • Drawings
    Embedded drawings will be in 3D space.

  • Bounded planes
    Bounded planes will be imported.

  • Unbounded planes
    Unbounded planes will be imported.

 

Forms and DialoguesDefault Directory

This sets the default directory for locating files to import of the specified type. Pick the folder icon to select a path from the Directory Browser. The path will be added to the Default directory field. The Default directory field only applies to the active session while VX is running unless it is permanently saved using the Save Settings button on the Import Form.
 
Clear Default directoryThis clears the Default Directory field.

More about the Default Directory

All import/export translators have their own default-directory on their options form.  If the default-directory is set, then the Directory Browser will always come up in that directory.  If the default-directory is not set, then the file browser will come up in the "last visited" directory.

The last visited directory is not unique.  There is one last visited for all import translators and one for all export translators.  By default, the value in the Default Directory field is set to ’.’ which means, use the "last visited" directory.  The file icon allows you to browse for a directory which will then be the new default.  You can set the Default Directory back to "." by selecting Reset on the form.
 
 

Forms and DialoguesOthers Options

  • OK
    Pick OK to accept the current selections and make them the defaults.

  • Reset
    Pick Reset to return all selections to the previous defaults.
Authored by: VXCADBase Help-Desk
Click Here to View all the articles in Importing Files category.
File Attachments File Attachments
There are no attachment file(s) related to this article.
Article Information Additional Information
Article Number: 195
Created: 27 Jan, 2008 12:30 PM
Last Modified: 28 Jan, 2010
Rating No Rating
Article Options Article Options
Print Question Print this Article del.icio.us Bookmark del.icio.us Bookmark
Email Question Email this Article to Friend Digg It Digg It
Export to MS Word Export to MS Word Furl It Furl It
Bookmark Article Subscribe to Article Subscribe to Article
 
Related Questions Related Articles
  1. General Import Options - CATIA 4,5 /SAT / NX / Inventor / Pro-e / SolidWorks
  2. AutoCAD Import Options - DWG / DXF
  3. General Import Options - Parasolid / PS2 / PS3 / STEP / VX Neutral / STL / SAT
  4. General Import Options - Pro/E
  5. Import
  6. General Import Options
  7. Split STL File
  8. TM Import Options - CATIA 4, 5, Pro/E and Unigraphics
  9. Import Tips & Techniques
  10. Import Objects Filter
  11. Import Configuration
  12. Image Import Options
  13. VDA Import Options
 
 

Powered by VX CAD/CAM