Home > All Categories > 12. VX Import & Export > Importing Files > TM Import Options - CATIA 4, 5, Pro/E and Unigraphics
Question Title TM Import Options - CATIA 4, 5, Pro/E and Unigraphics

In this Article:

 
 

TM Import Options - CATIA 4, 5, Pro/E and Unigraphics

File > Import > Set Options

Use these forms to perform various tasks while importing CATIA version 4, Catia version 5, Pro/E, and Unigraphics and SAT files. Complete the form as desired. Pick OK to accept the current selections as the new defaults or Reset to return all selections to their previous defaults.
 
 
TM Catia v4 Import Options
TM Catia v4 Import Options
TM Catia v5 Import Options
TM Catia v5 Import Options
TM Pro/E Import Options
TM Pro/E Import Options
TM UG Import Options
TM UG Import Options
TM SAT Import Options
TM SAT Import Options

 

 

 
 
 

Forms and Dialogues General Options

  • Auto sew geometry
    Closed surface volumes will be sewed (joined) at their mating edges to form a solid once they have been imported into VX. This option requires that the imported edges fall within tolerance of each other.

    If importing directly into an existing object or one that is currently active, the default tolerance displayed in the Part Settings Form is used. If importing into a new object (created during the import), the default system tolerance (0.1mm) is used.

  • Auto activate part
    The imported file will be automatically activated for editing (i.e., it will become the active part).

  • Rename layer collisions
    If the import file is being merged into the active part or drawing sheet and it contains references to layer names that already exist, the import file layer name references are renamed. If this option is not checked, then the contents of the layers are merged with the existing layers.

  • Remove duplicate surfaces
    If there are duplicate trimmed surfaces, the duplicate is thrown away if this option is selected; otherwise, the duplicates goes to a layer named ’DUPLICAT’.

  • Break trim edges
    Trim loops will be evaluated for tangent discontinuities and broken if required.

 

Forms and Dialogues Healing Options

  • None, Lite, Full
    VX can fix many problems with imported geometry automatically.  Select from None, Lite or Full healing.  See Using Heal Options During Import for a good procedure to follow during import.

  • Assembly Repair
    Check this box if the imported file is an assembly and you encounter assemply related object/file hirerachy problems.  This may help solve the problem.

 

Forms and Dialogues Read Options

Use these options to tell VX to Raed or Ignore certain types of data located within the import file.  Here are some data types you can read or ignore:
  • No-Show Entities
  • No-Pick Entities
  • Point Entities
  • All Workspaces
  • Non-Root Entities
  • Extra Root Entities
  • Free Edges
  • Free Vertices
  • Hidden Entities
  • Blanked Part
  • Invisible Layers

Forms and Dialogues Additional Options (Pro/E)
  • Resurface Splines
    If the imported file contains spline surfaces, use this option to have VX re-surface using the spline data contained in the file.

  • Read Free Surfaces
    Similar to the Read options above, check this box to Read or Ignore any free (unbounded) surfaces during the import.

 

Forms and DialoguesDefault Directory

This sets the default directory for locating files to import of the specified type. Pick the folder icon to select a path from the Directory Browser. The path will be added to the Default Directory Field. The Default directory field only applies to the active session while VX is running unless it is permanently saved using the Save Settings button on the Import Form.
 
 
 

More about the Default Directory

All import/export translators have their own default-directory on their options form. If the default-directory is set, then the Directory Browser will always come up in that directory. If the default-directory is not set, then the file browser will come up in the "last visited" directory.

The last visited directory is not unique. There is one last visited for all import translators and one for all export translators. By default, the value in the Default Directory field is set to ’.’ which means, use the "last visited" directory. The file icon allows you to browse for a directory which will then be the new default. You can set the Default Directory back to "." by selecting Reset on the form.
Authored by: VX Technical Support
Click Here to View all the articles in Importing Files category.
File Attachments File Attachments
There are no attachment file(s) related to this article.
Article Information Additional Information
Article Number: 197
Created: 27 Jan, 2008 12:40 PM
Last Modified: 17 Jul, 2009
Rating No Rating
Article Options Article Options
Print Question Print this Article del.icio.us Bookmark del.icio.us Bookmark
Email Question Email this Article to Friend Digg It Digg It
Export to MS Word Export to MS Word Furl It Furl It
Bookmark Article Subscribe to Article Subscribe to Article
 
Related Questions Related Articles
  1. General Import Options - CATIA 4,5 /SAT / NX / Inventor / Pro-e / SolidWorks
  2. AutoCAD Import Options - DWG / DXF
  3. General Import Options - Parasolid / PS2 / PS3 / STEP / VX Neutral / STL / SAT
  4. General Import Options - Pro/E
  5. Import
  6. General Import Options
  7. Split STL File
  8. Import Tips & Techniques
  9. Import Objects Filter
  10. Import Configuration
  11. IGES Import Options
  12. Image Import Options
  13. VDA Import Options
 
 